3G3RX2-A2004 | Closed loop V/f, Closed loop vector, Open loop V/f, Open loop vector | 230 V three phase | 0.4 kW | 0.75 kW | YES | IP20 | NO | Induction or asynchronous motor, Permanent magnet motor | As inverter option | Serial RS-485, USB | MODBUS/TCP, PROFIBUS DP Slave, PROFINET Slave | 255 mm | 150 mm | 140 mm | 3000 g |
3G3RX2-A2007 | Closed loop V/f, Closed loop vector, Open loop V/f, Open loop vector | 230 V three phase | 0.75 kW | 1.5 kW | YES | IP20 | NO | Induction or asynchronous motor, Permanent magnet motor | As inverter option | Serial RS-485, USB | MODBUS/TCP, PROFIBUS DP Slave, PROFINET Slave | 255 mm | 150 mm | 140 mm | 3000 g |
3G3RX2-A2015 | Closed loop V/f, Closed loop vector, Open loop V/f, Open loop vector | 230 V three phase | 1.5 kW | 2.2 kW | YES | IP20 | NO | Induction or asynchronous motor, Permanent magnet motor | As inverter option | Serial RS-485, USB | MODBUS/TCP, PROFIBUS DP Slave, PROFINET Slave | 255 mm | 150 mm | 140 mm | 3000 g |
3G3RX2-A2022 | Closed loop V/f, Closed loop vector, Open loop V/f, Open loop vector | 230 V three phase | 2.2 kW | 3.7 kW | YES | IP20 | NO | Induction or asynchronous motor, Permanent magnet motor | As inverter option | Serial RS-485, USB | MODBUS/TCP, PROFIBUS DP Slave, PROFINET Slave | 255 mm | 150 mm | 140 mm | 3000 g |
3G3RX2-A2037 | Closed loop V/f, Closed loop vector, Open loop V/f, Open loop vector | 230 V three phase | 3.7 kW | 5.5 kW | YES | IP20 | NO | Induction or asynchronous motor, Permanent magnet motor | As inverter option | Serial RS-485, USB | MODBUS/TCP, PROFIBUS DP Slave, PROFINET Slave | 255 mm | 150 mm | 140 mm | 3000 g |
3G3RX2-A2055 | Closed loop V/f, Closed loop vector, Open loop V/f, Open loop vector | 230 V three phase | 5.5 kW | 7.5 kW | YES | IP20 | NO | Induction or asynchronous motor, Permanent magnet motor | As inverter option | Serial RS-485, USB | MODBUS/TCP, PROFIBUS DP Slave, PROFINET Slave | 260 mm | 210 mm | 170 mm | 6000 g |
3G3RX2-A2075 | Closed loop V/f, Closed loop vector, Open loop V/f, Open loop vector | 230 V three phase | 7.5 kW | 11 kW | YES | IP20 | NO | Induction or asynchronous motor, Permanent magnet motor | As inverter option | Serial RS-485, USB | MODBUS/TCP, PROFIBUS DP Slave, PROFINET Slave | 260 mm | 210 mm | 170 mm | 6000 g |
3G3RX2-A2110 | Closed loop V/f, Closed loop vector, Open loop V/f, Open loop vector | 230 V three phase | 11 kW | 15 kW | YES | IP20 | NO | Induction or asynchronous motor, Permanent magnet motor | As inverter option | Serial RS-485, USB | MODBUS/TCP, PROFIBUS DP Slave, PROFINET Slave | 260 mm | 210 mm | 170 mm | 6000 g |
3G3RX2-A2150 | Closed loop V/f, Closed loop vector, Open loop V/f, Open loop vector | 230 V three phase | 15 kW | 18.5 kW | YES | IP20 | NO | Induction or asynchronous motor, Permanent magnet motor | As inverter option | Serial RS-485, USB | MODBUS/TCP, PROFIBUS DP Slave, PROFINET Slave | 390 mm | 245 mm | 190 mm | 10000 g |
3G3RX2-A2185 | Closed loop V/f, Closed loop vector, Open loop V/f, Open loop vector | 230 V three phase | 18.5 kW | 22 kW | YES | IP20 | NO | Induction or asynchronous motor, Permanent magnet motor | As inverter option | Serial RS-485, USB | MODBUS/TCP, PROFIBUS DP Slave, PROFINET Slave | 390 mm | 245 mm | 190 mm | 10000 g |
3G3RX2-A2220 | Closed loop V/f, Closed loop vector, Open loop V/f, Open loop vector | 230 V three phase | 22 kW | 30 kW | YES | IP20 | NO | Induction or asynchronous motor, Permanent magnet motor | As inverter option | Serial RS-485, USB | MODBUS/TCP, PROFIBUS DP Slave, PROFINET Slave | 390 mm | 245 mm | 190 mm | 10000 g |
3G3RX2-A2300 | Closed loop V/f, Closed loop vector, Open loop V/f, Open loop vector | 230 V three phase | 30 kW | 37 kW | YES | IP20 | NO | Induction or asynchronous motor, Permanent magnet motor | As inverter option | Serial RS-485, USB | MODBUS/TCP, PROFIBUS DP Slave, PROFINET Slave | 540 mm | 300 mm | 195 mm | 22000 g |
3G3RX2-A2370 | Closed loop V/f, Closed loop vector, Open loop V/f, Open loop vector | 230 V three phase | 37 kW | 45 kW | YES | IP20 | NO | Induction or asynchronous motor, Permanent magnet motor | As inverter option | Serial RS-485, USB | MODBUS/TCP, PROFIBUS DP Slave, PROFINET Slave | 550 mm | 390 mm | 250 mm | 33000 g |
3G3RX2-A2450 | Closed loop V/f, Closed loop vector, Open loop V/f, Open loop vector | 230 V three phase | 45 kW | 55 kW | YES | IP20 | NO | Induction or asynchronous motor, Permanent magnet motor | As inverter option | Serial RS-485, USB | MODBUS/TCP, PROFIBUS DP Slave, PROFINET Slave | 550 mm | 390 mm | 250 mm | 33000 g |
3G3RX2-A2550 | Closed loop V/f, Closed loop vector, Open loop V/f, Open loop vector | 230 V three phase | 55 kW | 75 kW | YES | IP20 | NO | Induction or asynchronous motor, Permanent magnet motor | As inverter option | Serial RS-485, USB | MODBUS/TCP, PROFIBUS DP Slave, PROFINET Slave | 700 mm | 480 mm | 250 mm | 47000 g |
3G3RX2-A4007 | Closed loop V/f, Closed loop vector, Open loop V/f, Open loop vector | 400 V three phase | 0.75 kW | 1.5 kW | YES | IP20 | NO | Induction or asynchronous motor, Permanent magnet motor | As inverter option | Serial RS-485, USB | MODBUS/TCP, PROFIBUS DP Slave, PROFINET Slave | 255 mm | 150 mm | 140 mm | 3000 g |
3G3RX2-A4015 | Closed loop V/f, Closed loop vector, Open loop V/f, Open loop vector | 400 V three phase | 1.5 kW | 2.2 kW | YES | IP20 | NO | Induction or asynchronous motor, Permanent magnet motor | As inverter option | Serial RS-485, USB | MODBUS/TCP, PROFIBUS DP Slave, PROFINET Slave | 255 mm | 150 mm | 140 mm | 3000 g |
3G3RX2-A4022 | Closed loop V/f, Closed loop vector, Open loop V/f, Open loop vector | 400 V three phase | 2.2 kW | 3.7 kW | YES | IP20 | NO | Induction or asynchronous motor, Permanent magnet motor | As inverter option | Serial RS-485, USB | MODBUS/TCP, PROFIBUS DP Slave, PROFINET Slave | 255 mm | 150 mm | 140 mm | 3000 g |
3G3RX2-A4037 | Closed loop V/f, Closed loop vector, Open loop V/f, Open loop vector | 400 V three phase | 3.7 kW | 5.5 kW | YES | IP20 | NO | Induction or asynchronous motor, Permanent magnet motor | As inverter option | Serial RS-485, USB | MODBUS/TCP, PROFIBUS DP Slave, PROFINET Slave | 255 mm | 150 mm | 140 mm | 3000 g |
3G3RX2-A4055 | Closed loop V/f, Closed loop vector, Open loop V/f, Open loop vector | 400 V three phase | 5.5 kW | 7.5 kW | YES | IP20 | NO | Induction or asynchronous motor, Permanent magnet motor | As inverter option | Serial RS-485, USB | MODBUS/TCP, PROFIBUS DP Slave, PROFINET Slave | 260 mm | 210 mm | 170 mm | 6000 g |
3G3RX2-A4075 | Closed loop V/f, Closed loop vector, Open loop V/f, Open loop vector | 400 V three phase | 7.5 kW | 11 kW | YES | IP20 | NO | Induction or asynchronous motor, Permanent magnet motor | As inverter option | Serial RS-485, USB | MODBUS/TCP, PROFIBUS DP Slave, PROFINET Slave | 260 mm | 210 mm | 170 mm | 6000 g |
3G3RX2-A4110 | Closed loop V/f, Closed loop vector, Open loop V/f, Open loop vector | 400 V three phase | 11 kW | 15 kW | YES | IP20 | NO | Induction or asynchronous motor, Permanent magnet motor | As inverter option | Serial RS-485, USB | MODBUS/TCP, PROFIBUS DP Slave, PROFINET Slave | 260 mm | 210 mm | 170 mm | 6000 g |
3G3RX2-A4150 | Closed loop V/f, Closed loop vector, Open loop V/f, Open loop vector | 400 V three phase | 15 kW | 18.5 kW | YES | IP20 | NO | Induction or asynchronous motor, Permanent magnet motor | As inverter option | Serial RS-485, USB | MODBUS/TCP, PROFIBUS DP Slave, PROFINET Slave | 390 mm | 245 mm | 190 mm | 8500 g |
3G3RX2-A4185 | Closed loop V/f, Closed loop vector, Open loop V/f, Open loop vector | 400 V three phase | 18.5 kW | 22 kW | YES | IP20 | NO | Induction or asynchronous motor, Permanent magnet motor | As inverter option | Serial RS-485, USB | MODBUS/TCP, PROFIBUS DP Slave, PROFINET Slave | 390 mm | 245 mm | 190 mm | 8500 g |
3G3RX2-A4220 | Closed loop V/f, Closed loop vector, Open loop V/f, Open loop vector | 400 V three phase | 22 kW | 30 kW | YES | IP20 | NO | Induction or asynchronous motor, Permanent magnet motor | As inverter option | Serial RS-485, USB | MODBUS/TCP, PROFIBUS DP Slave, PROFINET Slave | 390 mm | 245 mm | 190 mm | 8500 g |
3G3RX2-A4300 | Closed loop V/f, Closed loop vector, Open loop V/f, Open loop vector | 400 V three phase | 30 kW | 37 kW | YES | IP20 | NO | Induction or asynchronous motor, Permanent magnet motor | As inverter option | Serial RS-485, USB | MODBUS/TCP, PROFIBUS DP Slave, PROFINET Slave | 540 mm | 300 mm | 195 mm | 22000 g |
3G3RX2-A4370 | Closed loop V/f, Closed loop vector, Open loop V/f, Open loop vector | 400 V three phase | 37 kW | 45 kW | YES | IP20 | NO | Induction or asynchronous motor, Permanent magnet motor | As inverter option | Serial RS-485, USB | MODBUS/TCP, PROFIBUS DP Slave, PROFINET Slave | 550 mm | 390 mm | 250 mm | 31000 g |
3G3RX2-A4450 | Closed loop V/f, Closed loop vector, Open loop V/f, Open loop vector | 400 V three phase | 45 kW | 55 kW | YES | IP20 | NO | Induction or asynchronous motor, Permanent magnet motor | As inverter option | Serial RS-485, USB | MODBUS/TCP, PROFIBUS DP Slave, PROFINET Slave | 550 mm | 390 mm | 250 mm | 31000 g |
3G3RX2-A4550 | Closed loop V/f, Closed loop vector, Open loop V/f, Open loop vector | 400 V three phase | 55 kW | 75 kW | YES | IP20 | NO | Induction or asynchronous motor, Permanent magnet motor | As inverter option | Serial RS-485, USB | MODBUS/TCP, PROFIBUS DP Slave, PROFINET Slave | 550 mm | 390 mm | 250 mm | 31000 g |
3G3RX2-B411K | Closed loop V/f, Closed loop vector, Open loop V/f, Open loop vector | 400 V three phase | 110 kW | 132 kW | YES | IP00 | NO | Induction or asynchronous motor, Permanent magnet motor | As inverter option | Serial RS-485, USB | MODBUS/TCP, PROFIBUS DP Slave, PROFINET Slave | 740 mm | 480 mm | 270 mm | 53000 g |
3G3RX2-B413K | Closed loop V/f, Closed loop vector, Open loop V/f, Open loop vector | 400 V three phase | 132 kW | 160 kW | YES | IP00 | NO | Induction or asynchronous motor, Permanent magnet motor | As inverter option | Serial RS-485, USB | MODBUS/TCP, PROFIBUS DP Slave, PROFINET Slave | 740 mm | 480 mm | 270 mm | 53000 g |
3G3RX2-B4750 | Closed loop V/f, Closed loop vector, Open loop V/f, Open loop vector | 400 V three phase | 75 kW | 90 kW | YES | IP00 | NO | Induction or asynchronous motor, Permanent magnet motor | As inverter option | Serial RS-485, USB | MODBUS/TCP, PROFIBUS DP Slave, PROFINET Slave | 700 mm | 390 mm | 270 mm | 41000 g |
3G3RX2-B4900 | Closed loop V/f, Closed loop vector, Open loop V/f, Open loop vector | 400 V three phase | 90 kW | 110 kW | YES | IP00 | NO | Induction or asynchronous motor, Permanent magnet motor | As inverter option | Serial RS-485, USB | MODBUS/TCP, PROFIBUS DP Slave, PROFINET Slave | 700 mm | 390 mm | 270 mm | 41000 g |