Skip to content
MODEL | Door switch type | Guard-lock | Material housing | Ambient temperature (operating) | Door contacts NC | Door contacts NO | With LED indicator | Connection method | Cable length | Cable exit direction | Degree of protection (IP) | Switch without actuator |
F3S-TGR-NLMC-21-05 | Non-contact, Hall coded | No | Stainless steel | -25-105 °C | 2 | 1 | Yes | Cable | 5 m | Left | IP69K | No |
F3S-TGR-NLMC-21-M1J8 | Non-contact, Hall coded | No | Stainless steel | -25-105 °C | 2 | 1 | Yes | M12 pigtail connector | 0.25 m | Left | IP67 | No |
F3S-TGR-NLPC-20-02 | Non-contact, Hall coded | No | Polyester | -25-80 °C | 2 | 0 | Yes | Cable | 2 m | Left | IP69K | No |
F3S-TGR-NLPC-20-05 | Non-contact, Hall coded | No | Polyester | -25-80 °C | 2 | 0 | Yes | Cable | 5 m | Left | IP69K | No |
F3S-TGR-NLPC-20-10 | Non-contact, Hall coded | No | Polyester | -25-80 °C | 2 | 0 | Yes | Cable | 10 m | Left | IP69K | No |
F3S-TGR-NLPC-20-M1J8 | Non-contact, Hall coded | No | Polyester | -25-80 °C | 2 | 0 | Yes | M12 pigtail connector | 0.25 m | Left | IP67 | No |
F3S-TGR-NLPC-21-02 | Non-contact, Hall coded | No | Polyester | -25-80 °C | 2 | 1 | Yes | Cable | 2 m | Left | IP69K | No |
F3S-TGR-NLPC-21-05 | Non-contact, Hall coded | No | Polyester | -25-80 °C | 2 | 1 | Yes | Cable | 5 m | Left | IP69K | No |
F3S-TGR-NLPC-21-10 | Non-contact, Hall coded | No | Polyester | -25-80 °C | 2 | 1 | Yes | Cable | 10 m | Left | IP69K | No |
F3S-TGR-NLPC-21-M1J8 | Non-contact, Hall coded | No | Polyester | -25-80 °C | 2 | 1 | Yes | M12 pigtail connector | 0.25 m | Left | IP67 | No |
F3S-TGR-NMPC-20-02 | Non-contact, Hall coded | No | Polyester | -25-80 °C | 2 | 0 | Yes | Cable | 2 m | Left | IP69K | No |
F3S-TGR-NMPC-20-05 | Non-contact, Hall coded | No | Polyester | -25-80 °C | 2 | 0 | Yes | Cable | 5 m | Left | IP69K | No |
F3S-TGR-NMPC-20-10 | Non-contact, Hall coded | No | Polyester | -25-80 °C | 2 | 0 | Yes | Cable | 10 m | Left | IP69K | No |
F3S-TGR-NMPC-20-M1J8 | Non-contact, Hall coded | No | Polyester | -25-80 °C | 2 | 0 | Yes | M12 pigtail connector | 0.25 m | Left | IP67 | No |
F3S-TGR-NMPC-21-02 | Non-contact, Hall coded | No | Polyester | -25-80 °C | 2 | 1 | Yes | Cable | 2 m | Left | IP69K | No |
F3S-TGR-NMPC-21-05 | Non-contact, Hall coded | No | Polyester | -25-80 °C | 2 | 1 | Yes | Cable | 5 m | Left | IP69K | No |
F3S-TGR-NMPC-21-05-R | Non-contact, Hall coded | No | Polyester | -25-80 °C | 2 | 1 | Yes | Cable | 5 m | Right | IP69K | No |
F3S-TGR-NMPC-21-10 | Non-contact, Hall coded | No | Polyester | -25-80 °C | 2 | 1 | Yes | Cable | 10 m | Left | IP69K | No |
F3S-TGR-NMPC-21-M1J8 | Non-contact, Hall coded | No | Polyester | -25-80 °C | 2 | 1 | Yes | M12 pigtail connector | 0.25 m | Left | IP67 | No |
F3S-TGR-NMPC-21-M1J8-R | Non-contact, Hall coded | No | Polyester | -25-80 °C | 2 | 1 | Yes | M12 pigtail connector | 0.25 m | Right | IP67 | No |
F3S-TGR-NSMC-20-05 | Non-contact, Hall coded | No | Stainless steel | -25-105 °C | 2 | 0 | Yes | Cable | 5 m | Left | IP69K | No |
F3S-TGR-NSMC-20-10 | Non-contact, Hall coded | No | Stainless steel | -25-105 °C | 2 | 0 | Yes | Cable | 10 m | Left | IP69K | No |
F3S-TGR-NSMC-20-M1J8 | Non-contact, Hall coded | No | Stainless steel | -25-105 °C | 2 | 0 | Yes | M12 pigtail connector | 0.25 m | Left | IP67 | No |
F3S-TGR-NSMC-21-02 | Non-contact, Hall coded | No | Stainless steel | -25-105 °C | 2 | 1 | Yes | Cable | 2 m | Left | IP69K | No |
F3S-TGR-NSMC-21-05 | Non-contact, Hall coded | No | Stainless steel | -25-105 °C | 2 | 1 | Yes | Cable | 5 m | Left | IP69K | No |
F3S-TGR-NSMC-21-10 | Non-contact, Hall coded | No | Stainless steel | -25-105 °C | 2 | 1 | Yes | Cable | 10 m | Left | IP69K | No |
F3S-TGR-NSMC-21-M1J8 | Non-contact, Hall coded | No | Stainless steel | -25-105 °C | 2 | 1 | Yes | M12 pigtail connector | 0.25 m | Left | IP67 | No |
F3S-TGR-NSPC-21-05 | Non-contact, Hall coded | No | Polyester | -25-80 °C | 2 | 1 | Yes | Cable | 5 m | Left | IP69K | No |
F3S-TGR-NSPC-21-10 | Non-contact, Hall coded | No | Polyester | -25-80 °C | 2 | 1 | Yes | Cable | 10 m | Left | IP69K | No |
F3S-TGR-NSPC-21-M1J8 | Non-contact, Hall coded | No | Polyester | -25-80 °C | 2 | 1 | Yes | M12 pigtail connector | 0.25 m | Left | IP67 | No |