Skip to content
MODEL | Shape | Sensing method | Sensing distance | Sensing distance (min.) | Setting method | Connection method | Cable length | Output type | Operation mode | Response time | Material housing | Thread size | Width | Height | Depth | Type of light | Power supply voltage | Features | Degree of protection (IP) |
E3JK-DP11-2M | Cuboid | Diffuse reflective | 2500 mm | | Manual adjustment | Cable | 2 m | PNP | Dark-ON, Light-ON | 1 ms | ABS | Other | 18 mm | 52 mm | 50 mm | Polarity free red light | 10-30 V | | |
E3JK-DP12-2M | Cuboid | Diffuse reflective | 300 mm | | Manual adjustment | Cable | 2 m | PNP | Dark-ON, Light-ON | 1 ms | ABS | Other | 18 mm | 52 mm | 50 mm | Polarity free red light | 10-30 V | | |
E3JK-DP13-2M | Cuboid | Diffuse reflective | 2500 mm | | Manual adjustment | Cable | 2 m | PNP | Dark-ON, Light-ON | 1 ms | ABS | Other | 18 mm | 52 mm | 50 mm | Infrared light | 10-30 V | | |
E3JK-DR11-2M | Cuboid | Diffuse reflective | 2500 mm | | Manual adjustment | Cable | 2 m | Relay | Dark-ON, Light-ON | 20 ms | ABS | Other | 18 mm | 52 mm | 50 mm | Polarity free red light | 24-240 V | | |
E3JK-DR12-2M | Cuboid | Diffuse reflective | 300 mm | | Manual adjustment | Cable | 2 m | Relay | Dark-ON, Light-ON | 20 ms | ABS | Other | 18 mm | 52 mm | 50 mm | Polarity free red light | 24-240 V | | |
E3JK-DR13-2M | Cuboid | Diffuse reflective | 2500 mm | | Manual adjustment | Cable | 2 m | Relay | Dark-ON, Light-ON | 20 ms | ABS | Other | 18 mm | 52 mm | 50 mm | Infrared light | 24-240 V | | |
E3JK-DR14 2M | Cuboid | Diffuse reflective | 300 mm | | Manual adjustment | Cable | 2 m | Relay | Dark-ON, Light-ON | 20 ms | ABS | Other | 18 mm | 52 mm | 50 mm | Infrared light | 24-240 V | | |
E3JK-RN12-2M | Cuboid | Retro-reflective | 10000 mm | 100 mm | Manual adjustment | Cable | 2 m | NPN | Dark-ON, Light-ON | 1 ms | ABS | Other | 18 mm | 52 mm | 50 mm | Polarized red light | 10-30 V | M.S.R. | |
E3JK-RP11-2M | Cuboid | Retro-reflective | 11000 mm | 100 mm | Manual adjustment | Cable | 2 m | PNP | Dark-ON, Light-ON | 1 ms | ABS | Other | 18 mm | 52 mm | 50 mm | Polarity free red light | 10-30 V | Without M.S.R. | |
E3JK-RP12-2M | Cuboid | Retro-reflective | 10000 mm | 100 mm | Manual adjustment | Cable | 2 m | PNP | Dark-ON, Light-ON | 1 ms | ABS | Other | 18 mm | 52 mm | 50 mm | Polarized red light | 10-30 V | M.S.R. | |
E3JK-RR11-2M | Cuboid | Retro-reflective | 11000 mm | 100 mm | Manual adjustment | Cable | 2 m | Relay | Dark-ON, Light-ON | 20 ms | ABS | Other | 18 mm | 52 mm | 50 mm | Polarity free red light | 24-240 V | Without M.S.R. | |
E3JK-RR12-2M | Cuboid | Retro-reflective | 10000 mm | 100 mm | Manual adjustment | Cable | 2 m | Relay | Dark-ON, Light-ON | 20 ms | ABS | Other | 18 mm | 52 mm | 50 mm | Polarized red light | 24-240 V | M.S.R. | |
E3JK-RR12-5M | Cuboid | Retro-reflective | 10000 mm | 100 mm | Manual adjustment | Cable | 5 m | Relay | Dark-ON, Light-ON | 20 ms | ABS | Other | 18 mm | 52 mm | 50 mm | Polarized red light | 24-240 V | M.S.R. | |
E3JK-TP11-2M | Cuboid | Through-beam | 40000 mm | | Manual adjustment | Cable | 2 m | PNP | Dark-ON, Light-ON | 1 ms | ABS | Other | 18 mm | 52 mm | 50 mm | Polarity free red light | 10-30 V | | |
E3JK-TR11-2M | Cuboid | Through-beam | 40000 mm | | Manual adjustment | Cable | 2 m | Relay | Dark-ON, Light-ON | 20 ms | ABS | Other | 18 mm | 52 mm | 50 mm | Polarity free red light | 24-240 V | | IP64 |
E3JK-TR11-5M | Cuboid | Through-beam | 40000 mm | | Manual adjustment | Cable | 5 m | Relay | Dark-ON, Light-ON | 20 ms | ABS | Other | 18 mm | 52 mm | 50 mm | Polarity free red light | 24-240 V | | IP64 |
E3JK-TR12-2M | Cuboid | Through-beam | 5000 mm | | Manual adjustment | Cable | 2 m | Relay | Dark-ON, Light-ON | 20 ms | ABS | Other | | | | Polarity free red light | 24-240 V | | |